-40%
Omega CNiTH-i16D33-5 CONTROLLER,Temperature, RH Input, W ITHP-2 Temp Rh Sensor
$ 150.47
- Description
- Size Guide
Description
This is a listing forOmega CNiTH-i16D33-5 CONTROLLER,Temperature, RH Input, W ITHP-2 Temp Rh Sensor
What you will get:
Omega CNiTH-i16D33-5 CONTROLLER,Temperature, RH Input, W ITHP-2 Temp Rh Sensor
Description:
A Omega CNiTH-i16D33-5 CONTROLLER,Temperature, RH Input, W ITHP-2 Temp Rh Sensor system in excellent used condition.
More Information from the Omega sire
CONTROLLER,Temperature and RH Input 1/16 DIN Dual Display, 2 Relays: Form "C"SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, WITH 5" (137mm) Probe on 10ft (3m) cable
The OMEGA™ iTH Series instruments monitor and control both temperature and relative humidity. All controllers in the series are high quality, highly accurate instruments featuring Omega’s award-winning iSeries technology, uncompromising accuracy, backed by an extended 5-year warranty.
The instruments are simple to configure and use, while providing tremendous versatility and a wealth of powerful features.
With two full channels of PID control, these instruments are the perfect choice for environmental control applications such as test chambers, clinical storage, computer rooms, etc.
The iTH Series Controllers provide single output control for humidity and temperature and are easily programmed for any control or alarming requirement from simple on-off to full autotune PID control.
The iTH family controllers are available in four true DIN sizes: the ultra compact 1/32 DIN; the popular midsize 1/16 DIN square bezel with dual display; the 1/8 DIN vertical, and the 1/8 DIN horizontal with the big bright 21 mm digits.
The iTH Series LED displays can be programmed to change color between
GREEN
,
AMBER
, and
RED
at any setpoint or alarm point.
The iTH controller models offer a choice of 2 control or alarm outputs in almost any combination: solid state relays (SSR); form “C” SPDT (single pole double throw) relays; pulsed 10 Vdc output for use with an external SSR; or analog output selectable for control or retransmission of the process value.
The networking and communications options (highly recommended) include direct Ethernet LAN connectivity with an embedded Web server, and serial communications. The C24 serial communications option includes both RS232 and RS485. Protocols include both MODBUS
®
and a straightforward ASCII protocol. The C4EIT option includes both Ethernet and RS485 ASCII/MODBUS on one device.
The iTH Series controllers are designed for easy integration with popular industrial automation, data acquisition and control programs as well as Microsoft Visual Basic and Excel. Omega provides free configuration software which makes it fast and easy to get up and running. Available for download on the Web.
SPECIFICATIONS
Control
Action:
Reverse (heat) or direct (cool)
Modes:
Time and amplitude proportional control modes; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative with anti-reset windup and ON/OFF
Rate:
0 to 399.9 seconds
Reset:
0 to 3999 seconds
Cycle Time:
1 to 199 seconds; set to 0 for ON/OFF operation
Gain:
0.5 to 100% of span; setpoints 1 or 2
Damping:
0000 to 0008
Soak:
00.00 to 99.59 (HH:MM), or OFF
Ramp to Setpoint:
00.00 to 99.59 (HH:MM), or OFF
Autotune:
Operator initiated from front panel for 1 input at a time only
Outputs
There are two physical outputs: Output 1 = RH, Output 2 = Temp
Functions are set up as Outputs (PID or ON/OFF), or Alarms
Ordering output choices:
Relay:
250 Vac @ 3A or 30 Vdc @ 3A (resistive load); Form C SPDT
SSR:
20 to 265 Vac @ 0.05 - 0.5A (resistive load); continuous
DC Pulse:
Non-Isolated; 10 Vdc @ 20 mA (used with external SSR)
Analog Output (Output 1 only):
Non-Isolated, control or retransmission 0 to 10 Vdc or 0 to 20 mA;
500 ohm max, accuracy is ±1% of FS
Control Output 1 and 2
Operation:
Action:
Reverse (heat) or Direct (cool)
Modes:
Time and Amplitude Proportional Control Modes; selectable Manual or Auto PID, Proportional, Proportional with Integral, Proportional with Derivative with Anti-reset Windup and ON/OFF
Alarm 1 and 2 (Programmable)
1)
Alarms are used for color changing sequence of alarm status (visual alarm).
2)
Alarm functions are active, in addition to the color changing functions, if Output 1 & 2 are (menu) disabled.
3)
If Alarms are disabled, Output menus (PID or ON/OFF) are active. Color change is still active.
Operation:
High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations
-AL Limit Alarm Version:
Output 1 & 2 submenus used for PID are eliminated from menu. Color sequence based on alarm setpoints is still available.
Input
Relative Humidity Accuracy/Range:
±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100%
Hysteresis:
±1% RH
Non-linearity:
±3%
Temperature Accuracy/Range*:
±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F)
Resolution:
0.1%, 12-bit for RH; 0.1°C, 14 bit for temperature
Response Time:
8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature
* Note:
Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C.
Network and Serial Communications (For Options -C24, -C4EIT, -EIT)
Ethernet:
Standards compliance IEEE 802.3 10Base-T
Supported Protocols:
TCP/IP, ARP
RS232/RS422/RS485:
Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status
RS485:
Addressable from 0 to 199
Connection:
Screw terminals
General
A/D Conversion:
12-bit RH and 14-bit temp
Reading Rate:
2 samples per sec max
Digital Filter:
Programmable
Decimal Selection:
None, 0.1 for temp and humidity
Display:
4-digit, 9-segment LED
i32, i16D, i8DV:
10.2 mm (0.40")
i8:
21 mm (0.83")
i8DH:
10.2 mm (0.40") and 21 mm (0.83")
GREEN
,
AMBER
, and
RED
programmable colors for process variable, setpoint and temp units
Operating Temperature:
0 to 50°C (32 to 122°F), 90% RH non-condensing
Protection:
i32, i16D:
NEMA 4X (IP65) front bezel
i8DH, i8DV:
NEMA 1 (IP23) front bezel
Power:
Refer to ordering guide
No CE compliance above 60 Hz.
Please use the shipping calculator to determine shipping.
See my
Other Items
where I have other scientific and test equipment.
If you receive your item and it is not to your 100 Percent Satisfaction, please contact us before leaving feedback. I strive to make sure every transaction is a positive one!
I wanted to reach out and let you know that eBay is changing the way Sellers are rated. I am not overjoyed with what's happening, but I have to roll with it. IF you have a problem with my item, I would like you to use the "Contact Seller" link in the listing, or call me. Please don't open a case. Cases count against me even if they are resolved. I stand behind my items and will work out any problems that you may have with an item. So please contact me if you have a problem with an item I have sold you and don't use the eBay Case as a means of communication.
International Buyers, Please Note:
Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying.
These charges are normally collected by the delivering freight (shipping) company or when you pick the item up do not confuse them for additional shipping charges.
We do not mark merchandise values below value or mark items as "gifts".
US and International government regulations prohibit such behavior.